Model MRW-12 is Reclining Fuse Disconnector (Cut-out fuse).

Reclining fuse disconnectors-fuses are installed on the high-voltage side

of the distribution transformer, etc.; serve as a fuse for short circuits

and overloads, as well as a device for switching on and off the load current.

 

The main advantages of MRW-12 are:

  1. high degree of protection against overcurrent,
  2. high withstand voltage at industrial frequency,
  3. high lightning impulse withstand voltage,
  4. high mechanical strength

This product fully complies with IEC282-2.

Disconnector MRW-12-2

Our MRW-12 outdoor drop fuses composed of a base and an arc extinguishing

device. The lower end of the arc extinguishing tube is equipped with a spring

bracket that may rotate, which always keeps the fuse in a tense state to ensure

the self-locking of the arc extinguishing tube in the closing position, and the

circuit and the transformer are overloaded.

Or in a short circuit, the fuse is blown, and the fuse is quickly pulled out from the arc extinguishing tube. The arc extinguishing tube is designed to be exhausted

step by step to solve the contradiction between breaking and breaking large

and small currents on the same fuse.

 

Excellent conductivity

All copper casting part adopts bronze/brass, it has excellent mechanical strength

and excellent conductivity. All contact parts be silver-plated, it adopts convex design

on the contact surface, this design can reduce the contact resistance and ensure

excellent conductivity. The high-strength memory cooper alloy sheets can ensure

contact with lower contact smoothly and without any affecting when fuse drop out.

It adopts Arc-shortening copper rod to improve the interrupt capacity when

short-circuit fault.

 

Reliable load breaking capacity

For Load break type fuse cut-out, its arc chamber made of special reinforced nylon

material. It has good mechanical strength, anti-aging and flame retardant.

Suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.

 

Relevant international executive standards

All fuse cutouts we manufacture and test according to the latest international standard

IEC 60282-2:2008 & IEEE Std C37.41-2008 & IEEE Std C37.42-2009.

Parameters

 

Main parameters:

Model Rated voltage kv Rated current A Breaking capacity MVA Power frequency dry withstand voltage kvrms 1 min Power frequency humidity withstand voltage kvrms 1 min
upper limit lower limit
MRW-10/100 10 100 100 30 42 34
MRW-10/200 10 200 200 30 42 34
Model Rated voltage kv Rated current A Breaking current kA Impulse voltage BIL Power frequency withstand voltage kv Crawling distance mm
MRW4 12 100 6.3 110 42 320
MRW4 12 200 12.5 110 42 320
  • The altitude does not exceed 1000m;
  • Ambient temperature: -35C +40C;
  • Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;
  • Installation site: no fire, explosion hazard, chemical corrosive gas and well-ventilated place, The angle of inclination is not more than 30.

Note: When the above normal use conditions are exceeded, the user can negotiate with the company.

 

class=»iksweb»
Rated voltage(KV) Rated current(A) Rated interrupting current (KA) Lightning impulse withstand voltage to ground (BIL KV) Minimum power frequency withstand dry voltage to ground (KV) Minimum creepage distance(mm)
11-15 100/200 12 110 42 220
11-15 100/200 12 125 50 320
24-27 100/200 12 150 65 470
33-38 100/200 8 170 70 660
33-38 100/200 8 170 70 720
33-38 100/200 8 170 70 900

Solutions

 

MRW-12 outdoor disconnector (drop fuse) is an outdoor high voltage protection appliance. It is installed on the high-voltage side of the istribution transformer or on the branch and trunk lines of the distribution line, and is used for short-circuit and overload protection of the transformer and the line, as well as the split and combined load current.

The drop fuse is composed of two parts: an insulating bracket and a fuse tube. The static contacts are installed at both ends of the insulating bracket, and the moving contacts are installed at both ends of the fuse tube.

The fuse tube consists of an inner arc suppression tube and an outer layer. Phenolic paper tube or epoxy glass cloth tube. The pull-load drop-type fuse enhances the elastic auxiliary contact and arc extinguishing cover to divide and combine the load current.

Disconnector MRW-12-3 Disconnector MRW-12-4

When order, please indicate the detailed information as below listed:

  1. Rated voltage and rated current.
  2. Minimum creepage distance.
  3. The material of insulator.
  4. Please indicate whether arc-shortening rod should be fitted with fuse cut-out.
  5. Please indicate the type of mounting bracket.

Hot Tags: MGW disconnector, China, OEM supplier, manufacturers, factory, wholesale, disconnecting switch, switch disconnector, automation, grounding, retrofit

#mettz #mettzgroup #mrw #disconnector #electrical #switch #retrofit #10kV #12kV