Battery DC Series

  • Share:

Description

 

Battery DC Series is Deep Cycle Batteries.

Voltage class: 2V/6V/12V

Capacity range: 26Ah~3000Ah

Superior deep cycle design

Suitable for solar & wind energy, UPS, telecom systems, electric power systems, control systems, small or golf cars, etc.

 

Technical Features:

DC (AGM Deep Cycle) series is specially designed for frequent cyclic discharge. By using strong grids and specially designed active material, the DC series battery offers 30% more cyclic life than the standby series. It is suitable for UPS, solar & wind energy, telecom system, electric power system, electric vehicles, golf cars, etc.

 

Battery DC Series have a smaller volume by comparing other same capacity DC battery. In addition, different from normal battery, DC 12V12AH improve 30% more life, the battery also can handle other cyclic applications such as remote micro-grids, power backup system, emergency system etc. With our revolutionary unique heat sealing and TTP welding technology, the battery has perfect performance in maintenance-free, after 12 months; its storage still can reach to 64%, which is high cost-effective solutions for solar, wind power systems and other renewable energy systems. The battery has wide protected operation temperature ranges of -20℃ ( -4℉) to 50℃ ( 122℉). And the deep cycle battery reduce the monthly self-discharge rate below 2% at 25℃ ( 77℉) .

 

Advantages:

  1. High purity lead-tin alloy, reduce battery self-discharge rate and increase battery service life.
  2. ABS battery case made by raw material to increase battery service life.
  3. Heat sealing technique instead of glue sealing to increase the tightness and stability of battery.
  4. TTP technique not only reduce internal resistance and material cost but also increase battery life.
  5. Conduct four large current discharge texting before package to insure battery quality.
  6. Full charge before delivery. Buy and use it directly.

Parameters

 

Main Technical parameters:

     Model       Nominal Voltage Capacity   Dimension  Terminal
(Ah) Length Width Height Total Height
(V) mm inch mm inch mm inch mm inch
DC12-26 12 26 C20/1.75VPC 166 6.54 176 6.93 125 4.92 125 4.92 F3(M5) / F13-BP(M5)/T24(M5)
DC12-26S 12 26 C20/1.75VPC 165 6.50 125 4.92 174 6.85 174 6.85 F7(M8) / F11(M6)
DC12-28S 12 28 C20/1.75VPC 165 6.50 125 4.92 174 6.85 174 6.85 F7(M8) / F11(M6)
DC6-180 6 180 C20/1.75VPC 306 12.05 168 6.61 220 8.66 227 8.94 F12(M8)
DC6-200 6 200 C20/1.75VPC 322 12.68 177.5 6.99 226 8.90 231 9.09 F16(M8) / F14(M8)
DC6-225 6 225 C20/1.75VPC 322 12.68 177.5 6.99 226 8.90 231 9.09 F16(M8) / F14(M8)
DC6-225S 6 225 C20/1.75VPC 243 9.57 187 7.36 275 10.83 275 10.83 F14(M8)
DC12-40 12 40 C20/1.75VPC 198 7.80 166 6.54 169 6.65 169 6.65 F4(M5) / F11(M6)
DC12-40A 12 40 C20/1.75VPC 198 7.80 166 6.54 169 6.65 169 6.65 F4(M5) / F11(M6)
DC12-55 12 55 C20/1.75VPC 229 9.02 138 5.43 211 8.31 216 8.50 F15(M6) / F11(M6)
DC12-55A 12 55 C20/1.75VPC 229 9.02 138 5.43 211 8.31 216 8.50 F15(M6) / F11(M6)
DC12-65 12 65 C20/1.75VPC 350 13.78 167 6.57 182 7.17 182 7.17 F5(M8) / F11(M6)
DC12-80 12 80 C20/1.75VPC 350 13.78 167 6.57 182 7.17 182 7.17 F5(M8) / F11(M6)
DC12-100S 12 100 C20/1.75VPC 306.5 12.07 168.5 6.63 210 8.27 215 8.46 F15(M6) / F12(M8)
DC12-100SA 12 100 C20/1.75VPC 306.5 12.07 168.5 6.63 210 8.27 215 8.46 F15(M6) / F12(M8)
DC12-100 12 100 C20/1.75VPC 328 12.91 172 6.77 215 8.46 220 8.66 F5(M8) / F12(M8)
DC12-100A 12 100 C20/1.75VPC 328 12.91 172 6.77 215 8.46 220 8.66 F5(M8) / F12(M8)
DC12-120 12 120 C20/1.75VPC 407 16.02 177 6.97 225 8.86 225 8.86 F5(M8) / F12(M8)
DC12-120A 12 120 C20/1.75VPC 407 16.02 177 6.97 225 8.86 225 8.86 F5(M8) / F12(M8)
DC12-120S 12 114 C20/1.75VPC 328 12.91 172 6.77 215 8.46 220 8.66 F5(M8) / F12(M8)
DC12-120SA 12 114 C20/1.75VPC 328 12.91 172 6.77 215 8.46 220 8.66 F5(M8) / F12(M8)
DC12-134 12 134 C20/1.75VPC 340 13.39 173 6.81 280 11.02 287 11.30 F5(M8) / F12(M8)
DC12-145 12 145 C20/1.75VPC 340 13.39 173 6.81 280 11.02 287 11.30 F5(M8) / F12(M8)
DC12-150 12 150 C20/1.75VPC 483 19.02 170 6.69 241 9.49 242 9.53 F5(M8) / F12(M8)
DC12-150A 12 150 C20/1.75VPC 483 19.02 170 6.69 241 9.49 242 9.53 F5(M8) / F12(M8)
DC12-160 12 160 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-160A 12 160 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-180 12 180 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-180A 12 180 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-190 12 190 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-190H 12 190 C20/1.75VPC 532 20.94 207 8.15 214 8.43 219 8.62 F16(M8) / F12(M8)
DC12-200 12 200 C20/1.75VPC 522 20.55 240 9.45 219 8.62 224 8.82 F16(M8) / F10(M8)
DC12-200A 12 200 C20/1.75VPC 522 20.55 240 9.45 219 8.62 224 8.82 F16(M8) / F10(M8)
DC12-225 12 225 C20/1.75VPC 522 20.55 240 9.45 219 8.62 224 8.82 F16(M8) / F10(M8)
DC12-230 12 230 C20/1.75VPC 521 20.51 269 10.59 204 8.03 209 8.23 F10(M8)
DC12-260 12 260 C20/1.75VPC 521 20.51 268 10.55 220 8.66 225 8.86 F14(M8)
DC12-260H 12 260 C20/1.75VPC 521 20.51 268 10.55 220 8.66 225 8.86 F14(M8)
DC2-200 2 200 C10/1.80VPC 171 6.73 111 4.37 328 12.91 340 13.39 F10(M8)
DC2-250 2 250 C10/1.80VPC 171 6.73 111 4.37 328 12.91 340 13.39 F10(M8)
DC2-300 2 300 C10/1.80VPC 170 6.69 150 5.91 330 12.99 342 13.46 F10(M8)
DC2-400 2 400 C10/1.80VPC 170 6.69 150 5.91 330 12.99 342 13.46 F10(M8)
DC2-500 2 500 C10/1.80VPC 211 8.31 172 6.77 330 12.99 342 13.46 F10(M8)
DC2-600 2 600 C10/1.80VPC 241 9.49 172 6.77 330 12.99 342 13.46 F10(M8)
DC2-800 2 800 C10/1.80VPC 301 11.85 172 6.77 330 12.99 342 13.46 F10(M8)
DC2-1000 2 1000 C10/1.80VPC 410 16.14 172 6.77 330 12.99 342 13.46 F10(M8)
DC2-1200 2 1200 C10/1.80VPC 473 18.62 172 6.77 330 12.99 342 13.46 F10(M8)
DC2-1500 2 1500 C10/1.80VPC 355 13.98 337 13.27 330 12.99 342 13.46 F10(M8)
DC2-2000 2 2000 C10/1.80VPC 476 18.74 337 13.27 330 12.99 342 13.46 F10(M8)
DC2-2500 2 2500 C10/1.80VPC 476 18.74 337 13.27 330 12.99 342 13.46 F10(M8)
DC2-3000 2 3000 C10/1.80VPC 696 27.40 340 13.39 330 12.99 342 13.46 F10(M8)
FT12-55D 12 55 C10/1.80VPC 291 11.46 106 4.17 230 9.06 230 9.06 F11(M6)
FT12-90D 12 90 C10/1.80VPC 562 22.13 114 4.49 188 7.40 188 7.40 F6(M8)
FT12-100D 12 100 C10/1.80VPC 508 20.00 110 4.33 236 9.29 236 9.29 F14(M8)
FT12-100SD 12 100 C10/1.80VPC 410 16.14 109 4.29 285 11.22 293 11.54 F9(M8)
FT12-105D 12 105 C10/1.80VPC 508 20.00 110 4.33 236 9.29 236 9.29 F14(M8)/F8(M6)
FT12-110D 12 110 C10/1.80VPC 410 16.14 109 4.29 285 11.22 293 11.54 F9(M8)
FT12-150D 12 150 C10/1.80VPC 565 22.24 110 4.33 288 11.34 288 11.34 F9(M8)
FT12-160D 12 160 C10/1.80VPC 565 22.24 110 4.33 288 11.34 288 11.34 F9(M8)
FT12-180D 12 180 C10/1.80VPC 560 22.05 125 4.92 316 12.44 316 12.44 F14(M8)
FT12-185D 12 185 C10/1.80VPC 560 22.05 125 4.92 316 12.44 316 12.44 F9(M8)
FT12-100LD 12 100 C10/1.80VPC 410 16.14 109 4.29 285 11.22 293 11.54 F9(M8)
FT12-150LD 12 150 C10/1.80VPC 565 22.24 110 4.33 288 11.34 288 11.34 F9(M8)
FT12-185LD 12 185 C10/1.80VPC 560 22.05 125 4.92 316 12.44 316 12.44 F9(M8)

Solutions

 

DC series deep cycle long life VRLA AMG battery uses different super-c additives in the positive plates and special AGM separators, The DC series features 30-50% higher cyclic life with 12-15 years of float life when compared to the standard Duration range. This series is highly suited for very unreliable power applications requiring the batteries to provide extra cyclic life performance such as PV solar system applications, BTS system, small RE systems and electric vehicles.

 

Three years warranty for solar cycle use daily.

30% longer life than regular AGM lead acid battery.

Longer life and higher stability for deep cycle use.

Use Super-C additives lead plates: Deep discharge recovery capability.

Cycle usage: 50% DOD, >1200cycles.

> Construction for Solar AGM deep cycle battery.

 

DC series deep cycle AGM battery adopts unique grid structure, special super corrosion-resistant alloy and unique active material formula, which can improve the efficiency, so DC battery recover performance is excellent after deep discharge even discharge to empty, also with the advantage of high durability, enough capacity and long cycle life.

All in DC battery adopts high pure raw materials since original, so its self-discharge rate is very low below 3% every month.

The electrolyte adopts low density gel electrolyte and add particular electrolyte additive, so can lower the corrosion of lead plates by electrolyte, reduce the problem of stratification of electrolyte density, result in to improve the battery charge receive capacity and over discharge performance, finally can extend the battery cycle life on a higher level.

DC battery adopts unique radial grid structure and super thick lead plates, in order to extend battery cycle life. Enhancing lead plates thickness ensure that battery can realize self-protect of over discharge so can avoid battery over discharge.

It adopts patent technology of high strength tight assemble and 4BS lead paste, so can extend the battery cycle life obviously.

It adopts battery formation innovative technology so can reduce of the possibility of lead plates secondary pollution and improve the battery consistency.

DC battery adopts gas recombination technology and high reliable seal technology, ensure battery own super high seal reaction efficiency, no acid fog spill and no pollution.

METTZ Group stands as a consortium of Chinese electrical firms, renowned for its expertise in manufacturing electrical equipment. We are specialized in crafting a comprehensive suite of transmission and distribution equipment, covering a wide voltage range from 0.4 to 40.5 kV. Our commitment lies in delivering reliable and stable products to our clientele, encompassing vacuum circuit breakers (VCB), gas-insulated switchgear modular units (RMU), solid insulated switchgear (SIS) panels, air insulated switchgear (AIS) panels, and dry compressed air insulated switchgear panels (DIS).

Since our inception, METTZ Group has been at the forefront of adopting international cutting-edge technologies and equipment. We pride ourselves on our extensive collaboration and dialogue with leading experts in the electrical technology sector, both within China and internationally. Our offerings are tailored to meet the specific needs of our clients, including Original Equipment Manufacturer (OEM) services, customization of products to unique parameters and dimensions, all in alignment with our customers’ specifications.

METTZ Group is dedicated to innovation, quality, and customer satisfaction, ensuring that we remain a preferred partner for electrical equipment solutions worldwide.

Hot Tags: Battery; China; OEM supplier; manufacturers; factory; wholesale; switchgear; cabinet; automation; substation; retrofit; DC; shell; electrical equipment; distribution; transmission; accumulator; Deep Cycle battery; Deep Cycle Lead Acid Battery; Deep Cycle Rechargeable Battery; Deep Cycling battery; Emergency Lighting Battery Pack; Solar Panels Storage Battery;  wholesale;

 

#mettz #mettzgroup #UPS #substation #switchgear #battery #AGM #electrical #distribution #accumulator #power #1kV